P0D11
Battery Charging System Negative Contactor A Control Circuit/Open
What it means
P0D11 means Battery Charging System Negative Contactor A Control Circuit/Open.
Check these first
- An open in the battery charging negative contactor A control circuit
- A failed battery energy control module
- A high voltage contactor that will not close
- An open or short in the battery energy control module harness
What to do next
- Read hybrid/EV battery contactor states on a scan tool
- Check the negative contactor state with the ignition cycled
- Inspect the battery energy control module connector and harness
- Test the negative contactor A control circuit for open and short faults
- Replace the battery energy control module if the circuit tests good
- Clear the code and retest
Look up another code
Enter a full code or a symptom. Press / to search. How to read a code
Type a code above, or start from a symptom or a common code.
Updated
Generic SAE J2012 definition. Last updated 2026-10-10.