EGR C Control Stuck Closed

System
Ignition and misfire (P code)
Lamp
Check Engine Light
Category
Powertrain - Ignition

What it means

P23E6 means EGR C Control Stuck Closed.

Check these first

  • Carbon or soot locking the EGR C valve closed
  • A failed EGR C actuator that cannot open the valve
  • A blocked EGR C passage or tube
  • A stuck EGR C pintle from heavy deposits

What to do next

  1. Command the EGR C valve open and watch actual position
  2. Inspect the EGR C valve and passages for carbon
  3. Clean the EGR C valve and port of deposits
  4. Check the EGR C actuator for free movement
  5. Replace the EGR C valve if it stays closed after cleaning
  6. Clear the code and retest