P2407
EVAP System Leak Detection Pump Sense Circuit Intermittent/Erratic
What it means
P2407 means EVAP System Leak Detection Pump Sense Circuit Intermittent/Erratic.
Where it lives
For P2407, the pump sits on the circuit this code reports. The description of P2407 reports a fault at the pump.
Check these first
- A loose connection at the leak detection pump sense connector
- A failing leak detection pump with an unstable output
- Chafed wiring grounding the pump sense signal
- Moisture tracked into the pump connector
What to do next
- Watch the pump sense signal on a scan tool while wiggling the harness
- Inspect the pump sense connector for loose pins
- Check the harness for chafing or moisture
- Test the pump output for stability
- Replace the leak detection pump if the circuit checks good
- Clear the code and retest
Look up another code
Enter a full code or a symptom. Press / to search. How to read a code
Type a code above, or start from a symptom or a common code.
Updated
Generic SAE J2012 definition. Last updated 2026-10-10.