OBD Codes List

Diagnostic reference · P240A

P240A

EVAP System Leak Detection Pump Heater Control Circuit/Open

System
Auxiliary emission controls (P code)
Lamp
Check Engine Light
Category
Powertrain - Auxiliary Emissions Controls

What it means

P240A means EVAP System Leak Detection Pump Heater Control Circuit/Open.

Where it lives

For P240A, the pump sits on the circuit this code reports. The description of P240A reports the pump as open.

Check these first

  • An open in the leak detection pump heater control wire
  • A failed leak detection pump heater
  • A backed out pin at the heater connector
  • A missing control module output to the heater

What to do next

  1. Command the leak detection pump heater with a scan tool
  2. Check continuity of the heater control wire
  3. Measure the heater element resistance
  4. Inspect the heater connector pins
  5. Replace the leak detection pump if the heater circuit is good
  6. Clear the code and retest

Look up another code

Enter a full code or a symptom. Press / to search. How to read a code

Type a code above, or start from a symptom or a common code.

Updated

Generic SAE J2012 definition. Last updated 2026-10-10.