EVAP System Leak Detection Pump Heater Control Circuit/Open
What it means
P240A means EVAP System Leak Detection Pump Heater Control Circuit/Open.
Where it lives
For P240A, the pump sits on the circuit this code reports. The description of P240A reports the pump as open.
Check these first
- An open in the leak detection pump heater control wire
- A failed leak detection pump heater
- A backed out pin at the heater connector
- A missing control module output to the heater
What to do next
- Command the leak detection pump heater with a scan tool
- Check continuity of the heater control wire
- Measure the heater element resistance
- Inspect the heater connector pins
- Replace the leak detection pump if the heater circuit is good
- Clear the code and retest